Supply Voltage (Nom) (V) 3.3, 5
No. of Tx 1
No. of Rx 1
Data Rate (kbps) 1000
HBM ESD (kV) 15
IEC 61000-4-2 Contact (±kV) 8
Int. Charge Pump
No. of Ext Caps 4
Nom Cap Value (µF) 0.1
Shutdown
Internal Caps
TTL Tri-State
Auto On-Line
VL Pin
Temperature Range (°C) -40 to 85
Package TSSOP-16
Show more

The SP3220E devices are RS-232 driver/receiver solutions intended for portable or hand-held applications such as palmtop computers, instrumentation and consumer products. These devices incorporate a high-efficiency charge-pump power supply that allows the SP3220E devices to deliver true RS-232 performance from a single power supply ranging from +3.0V to +5.0V. This charge pump requires only 0.1μF capacitors in 3.3V operation. The ESD tolerance of these devices is over ±15kV for both Human Model and IEC1000-4-2 Air discharge test methods. All devices have a low-power shutdown mode where the driver outputs and charge pumps are disabled. During shutdown, the supply current falls to less than 1μA.

  • Meets All EIA-232 and ITU V.28 Specifications from a wide +3.0V to +5.5V power supply
  • Interoperable with RS232 and V.28 at 2.7V
  • Supports High Serial Data Rates: 1 Mbps SP3220EU
  • 1μA Low Power Shutdown Mode
  • Footprint Compatible with MAX3221E, ISL3221
  • 4 x 0.1μF External Charge Pump Capacitors
  • Tri–State/Receiver Enable
  • Improved ESD Specifications:
    • +15kV Human Body Model
    • +15kV IEC1000-4-2 Air Discharge
    • +8kV IEC1000-4-2 Contact Discharge

Documentation & Design Tools

Type Title Version Date File Size
Data Sheets SP3220E/EB/EU +3.0V to +5.5V RS-232 Driver/Receiver Pair 1.0.3 May 2020 606.1 KB
Application Notes RS-232 and RS-485 PCB Layout Application Note R00 December 2022 2.8 MB
Application Notes ANI-10, Charge Pump Capacitor Selection Guide for 3V RS-232 Products B December 2006 71.8 KB
Product Brochures Interface Brochure November 2023 3.7 MB
Register for a myMxL account or Login to myMxL to view all Technical Documentation & Design Tools.

Quality & RoHS

Part Number RoHS | Exempt RoHS Halogen Free REACH TSCA MSL Rating / Peak Reflow Package
SP3220EUEY-L/TR N Y Y Y Y L1 / 260ᵒC TSSOP16

Click on the links above to download the Certificate of Non-Use of Hazardous Substances.

Additional Quality Documentation may be available, please Contact Support.

Parts & Purchasing

Part Number Pkg Code Min Temp Max Temp Status Suggested Replacement Buy Now Order Samples PDN
SP3220EUCA SSOP16 0 70 OBS
SP3220EUCA-L SSOP16 0 70 OBS SP3220EUCY-L
SP3220EUCA-L/TR SSOP16 0 70 OBS SP3220EUCY-L/TR
SP3220EUCA/TR SSOP16 0 70 OBS
SP3220EUCT WSOIC16 0 70 OBS
SP3220EUCT-L WSOIC16 0 70 OBS
SP3220EUCT-L/TR WSOIC16 0 70 OBS
SP3220EUCT/TR WSOIC16 0 70 OBS
SP3220EUCY TSSOP16 0 70 OBS
SP3220EUCY-L TSSOP16 0 70 OBS SP3220EUEY-L/TR
SP3220EUCY-L/TR TSSOP16 0 70 OBS SP3220EUEY-L/TR
SP3220EUCY/TR TSSOP16 0 70 OBS
SP3220EUEA SSOP16 -40 85 OBS
SP3220EUEA-L SSOP16 -40 85 OBS SP3220EUEY-L
SP3220EUEA-L/TR SSOP16 -40 85 OBS SP3220EUEY-L/TR
SP3220EUEA/TR SSOP16 -40 85 OBS
SP3220EUET WSOIC16 -40 85 OBS
SP3220EUET-L WSOIC16 -40 85 OBS
SP3220EUET-L/TR WSOIC16 -40 85 OBS
SP3220EUET/TR WSOIC16 -40 85 OBS
SP3220EUEY TSSOP16 -40 85 OBS
SP3220EUEY-L TSSOP16 -40 85 OBS SP3220EUEY-L/TR
SP3220EUEY-L/TR TSSOP16 -40 85 Active Order
SP3220EUEY/TR TSSOP16 -40 85 OBS
Show obsolete parts
Part Status Legend
Active - the part is released for sale, standard product.
EOL (End of Life) - the part is no longer being manufactured, there may or may not be inventory still in stock.
CF (Contact Factory) - the part is still active but customers should check with the factory for availability. Longer lead-times may apply.
PRE (Pre-introduction) - the part has not been introduced or the part number is an early version available for sample only.
OBS (Obsolete) - the part is no longer being manufactured and may not be ordered.
NRND (Not Recommended for New Designs) - the part is not recommended for new designs.

Packaging

Pkg Code Details Quantities Dimensions PDF
SSOP16
  • JEDEC Reference: MO-150
  • MSL Pb-Free: L2 @ 260ºC
  • MSL SnPb Eutectic: n/a
  • ThetaJA: 87ºC/W
  • Bulk Pack Style: Tube
  • Quantity per Bulk Pack: 76
  • Quantity per Reel: 1500
  • Quantity per Tube: 76
  • Quantity per Tray: n/a
  • Reel Size (Dia. x Width x Pitch): 330 x 16 x 12
  • Tape & Reel Unit Orientation: Quadrant 1
  • Dimensions: mm
  • Length: 6.20
  • Width: 5.30
  • Thickness: 2.00
  • Lead Pitch: 0.65
TSSOP16
  • JEDEC Reference: MO-153
  • MSL Pb-Free: L1 @ 260ºC
  • MSL SnPb Eutectic: n/a
  • ThetaJA: 100.4ºC/W
  • Bulk Pack Style: Tube
  • Quantity per Bulk Pack: 95
  • Quantity per Reel: 2500
  • Quantity per Tube: 95
  • Quantity per Tray: n/a
  • Reel Size (Dia. x Width x Pitch): 330 x 12 x 8
  • Tape & Reel Unit Orientation: Quadrant 1
  • Dimensions: mm
  • Length: 5.00
  • Width: 4.40
  • Thickness: 1.2
  • Lead Pitch: 0.65
WSOIC16
  • JEDEC Reference: MS-013
  • MSL Pb-Free: L3 @ 260ºC
  • MSL SnPb Eutectic: n/a
  • ThetaJA: 69.1ºC/W
  • Bulk Pack Style: Tube
  • Quantity per Bulk Pack: 47
  • Quantity per Reel: 1500
  • Quantity per Tube: 47
  • Quantity per Tray: n/a
  • Reel Size (Dia. x Width x Pitch): 330 x 16 x 12
  • Tape & Reel Unit Orientation: Quadrant 1
  • Dimensions: mm
  • Length: 10.30
  • Width: 7.50
  • Thickness: 2.65
  • Lead Pitch: 1.27

Notifications

Distribution Date Description File
05/10/2017 Qualification of alternate assembly subcon, JCET.
01/16/2017 Material Change. ANST qualified Mitsui as alternate lead frame supplier for TSSOP16L package, in addition to current qualified lead frame supplier FULL RIVER.
07/26/2016 Product discontinuation notification. Discontinued.
02/05/2016 Alternate assembly site. Addition of an alternate assembly supplier ANST (China)
07/03/2013 Addition of qualified 6 inch wafer processing line in Episil, in addition to the currently qualified 5 inch wafer processing line. Other change (foundry 6 inch wafer qualification).
05/23/2013 Qualified copper wire bonding assembly in addition to currently qualified gold wire bonding assembly in Carsem. Material change.
05/10/2011 Product Discontinuation Notice. Discontinued due to low market demand.
01/25/2010 Material Change; Product transfer to a qualified assembly supplier. To enhance production capacity and also to use environmentally friendly Green material.
12/14/2009 Material Change. Use environmental friendly Green (halogen free) material and also for standardization.
02/28/2007 Product Obsolescence Letter and Discontinuation Notification. Discontinued.
05/08/2006 Announcing transfer of certain Power Management and Interface Products from Hillview fabrication facility to wafer foundary Episil. See attached Product List Power Management and Interface products as listed are being transfer to external wafer foundry, due to cessation of operations of the sipex Hillview Fabrication manufacturing site
02/02/2006 Announcing transfer of certain Power Management and Interface Products from Hillview fabrication facility to wafer foundary Episil. See attached Product List Power Management and Interface products as listed are being transfer to external wafer foundry, due to cessation of operations of the sipex Hillview Fabrication manufacturing site

FAQs & Support

Search our list of FAQs for answers to common technical questions.
For material content, environmental, quality and reliability questions review the Quality tab or visit our Quality page.
For ordering information and general customer service visit our Contact Us page.

Submit a Technical Support Question As a New Question

For RS-232 it is 50 feet (15 meters), or the cable length equal to a capacitance of 2500 pF, at a maximum transmission rate of 19.2kbps. When we reduce the baud rate, it allows for longer cable length. For Example:

 

Baud Rate (bps)

Maximum RS-232 Cable Length (ft)

19200

50

9600

500

4800

1000

2400

3000

 
For RS-485 / RS-422 the data rate can exceed 10Mbps depending on the cable length. A cable length of 15 meters (50 feet) will do a maximum of 10Mbps. A cable length of 1200 meters (4000 feet) will do a maximum of 90kbps over 24 AWG gauge twisted pair cable (with 10 pF/ft). Refer to Annex A TIA/EIA-422-B. Also refer the RS-485 Cable Lengths vs. Data Signaling Rate Application Note (AN-292).
 
 

RS-232 uses both positive and negative voltages for signaling. The RS-232 driver needs a charge pump circuit to generate these signal voltages from a single Vcc supply. Four capacitors are needed to generate the positive (V+ or Vdd) and negative (V- or Vss) voltages.

ESD tests are “destructive tests.” The part is tested until it suffers damage. Therefore parts cannot be 100% tested in production, instead a sample of parts are characterized during the product qualification. The test procedure consists of “zapping” pins with a given voltage using the appropriate model and then running the part through electrical tests to check for functionality or performance degradation.

RS232 is the most widely implemented serial interface in the world. It is commonly installed as the serial port (9 pin or 25 pin) on PCs and has become ubiquitous on literally thousands of other applications. See below for comparisons.
 
Even though RS232 is a very old standard (first standardized in 1962) it is still popular because it is:
- simple, no software stack required, can be used to bring-up microcontrollers or load firmware on a “bare” system
- inexpensive, standard products exist from multiple vendors
- widely understood, support is already built in to most microcontrollers, the basics of serial communication are in most of the textbooks
- performance is adequate for many applications, simple data transfer, text or console ports, diagnostics, peripheral connectivity, etc.
 
However RS232 does have some limitations:
- It is slow by modern standards. Typical data rates are 1200 baud, 9600 baud, 115.2kbaud. High data rate RS232 devices are available up to 1Mbps. Faster speeds are uncommon.
- Signals swing to both positive and negative voltage. This requires an onboard charge pump to generate signals from a single power-supply chip or else multiple positive and negative supply rails.
- High pin-count per function. All signals are unidirectional and the charge pump requires several pins and external capacitors. So small footprint is difficult to achieve. Cables and connectors use more pins and wires than most modern serial protocols.
- Point-to-point only. Signals go from one driver to one receiver. RS232 does not support bi-directional signals or multiple drivers or receivers.
- Limited distance. RS232 uses single-ended signals which makes it difficult to support long cables. Typical RS232 cables are only about 10 meter or less. High speed (1Mbps) are typically less than 1 meter. The wide driver signal swing makes crosstalk a problem. Unbalanced signals with a shared ground reference are less able to withstand ground shifts between driver and receiver.
- Comparatively high power consumption. The wide signal swing takes quite a bit of power. By the RS232, signals idle at mark-state and receivers have typical 5kΩ impedance to ground, therefore drivers are constantly sourcing current even while idle. Many later RS232 transceivers’ feature shutdown modes or automatic power saving features (such as Auto On-Line, Auto On-Line Plus, Intelligent charge pumps, etc.). However some of the most commoditized devices lack any shutdown function.
 
RS485 overcomes most of the limitations of RS232 and is an excellent complement to RS232.
- RS485 uses differential signaling and is capable of much higher data rates (up to 20Mbit/sec)
- Differential signals also allow RS485 to communicate over 1200 meter cable lengths. Longer runs are possible with some careful system optimization.
- Bi-directional and multi-drop operation. RS485 can be used to build multidrop networks with many transmitters and many receivers.
- Balanced differential signalling also makes RS485 highly immune to noise. On twisted-pair cables a noise signal will couple equally to both wires in the pair and be ignored by the differential receiver.
 
RS485 is found mainly in industrial, telecom and commercial applications and is not as widespread in the consumer
or PC world. Therefore it is not seen as often as RS232.
 
Also the RS485 protocol standard defines only the electrical characteristics of the interface. The physical and logical implementations are left up to the user. Different connectors, different methods for bus-arbitration and data framing all exist under a wide variety of implementations. RS485 has also been used as the foundation for many proprietary or semi-proprietary standards. Therefore interoperability between RS485 based interfaces is not always as simple as with RS232.

ESD is caused by static electricity. In order for an ESD event to occur there must be a buildup of static charge. Very high charge levels are actually quite rare. In a normal factory environment, taking basic ESD precautions (grounding-straps, anti-static smocks, ionizers, humidity control, etc.) static levels can be kept below a few tens of volts. In an uncontrolled environment, like an office, static levels rarely get above 2000 volts. Under some worstcase conditions (wearing synthetic fabrics, rubbing against synthetic upholstered furniture, extremely low humidity)
levels can go as high as 12 to 15 thousand volts. Actually to get to 15000 volts or higher you would need to be in an uncomfortably dry environment (humidity below 10%) otherwise static charge will naturally dissipate through corona discharge. It would definitely be considered a “bad hair day.” Humans can generally feel a static shock only above 3000 volts. A discharge greater than 4000 volts can cause an audible “pop.” But repeated lower level discharges can be imperceptible and still may have a cumulative damaging effect on sensitive ICs. All ICs, even those with robust protection, can be damaged if they are hit hard enough or often enough.

Most ICs in a typical system are at greatest risk of ESD damage in the factory when the PCB is assembled and the system is being built. After the system is put together they are soldered onto the PCB and shielded within a metal or plastic system enclosure. Interface ICs are designed to attach to an external connector that could be exposed to ESD when a cable is plugged in or when a person or object touches the connector. These interface pins are most likely to see ESD exposure and therefore benefit from additional protection.

Visit the product page for the part you are interested in.  The part's status is listed in the Parts & Purchasing section.  You can also view Product Lifecycle and Obsolescence Information including PDNs (Product Discontinuation Notifications).
 
To visit a product page, type the part into the search window on the top of the MaxLinear website.
 
In this example, we searched for XRA1201.  Visit the product page by clicking the part number or visit the orderable parts list by clicking "Orderable Parts". 
 
 
 

 

  

The Parts & Purchasing section of the product page shows the Status of all orderable part numbers for that product.  Click Show obsolete parts, to see all EOL or OBS products.